CASBJ Error Messages

Message Description Resolution
CASBJ0000I message This is an ad hoc message for the JES subsystem None
CASBJ0001I Batch Input Spool has been "cold-started" An existing Input Spool Repository for this Server was not found and therefore a new one was created. The Input Spool Repository is effectively in a "cold start" condition. None
CASBJ0002E JCL parser not available The batch JCL parser is not available on this server Correct the installation
CASBJ0003E JOBjob-number duplicates an existing job number The Job Entry Subsystem generated a job number that duplicates an existing job number. Retry the submission
CASBJ0004I JOBjob-number job-name class job-class, TYPRUN=type-run The Job Entry Subsystem accepted the submitted job None
CASBJ0005I Batch initiator started for job classes "job-classes" The batch initiator was started an is available for processing MVS JCL and native batch scripts. Jobs will be selected from classes job-classes. None
CASBJ0006I Batch initiator initialization started The batch initiator process initialization started None
CASBJ0007S Error return-code during initialization of server PCA An error occurred whilst initializing the server's Process Control Area. The server will not complete its initialization. Make sure that the region for which the server was to be started is running and retry.
CASBJ0008I Batch Input Spool has been "cold-started" An existing Input Spool Repository for this Server was not found and therefore a new one was created. The Input Spool Repository is effectively in a "cold start" condition. None
CASBJ0009I Batch initiator shutdown complete. The batch initiator server process has shutdown normally. None.
CASBJ0010E Batch Spool File Error; Status action-status. The batch execution server failed trying to open the Spool reference file. The action and status are: action-status Correct the problem with the spool file and retry
CASBJ0011E Batch Spool File Error; Status action-status. The batch execution server failed trying to close the Spool reference file. The action and status are: action-status Correct the problem with the spool file and retry
CASBJ0012I Batch Input Spool has been "cold-started" An existing Input Spool Repository for this Server was not found and therefore a new one was created. The Input Spool Repository is effectively in a "cold start" condition. None
CASBJ0013E Batch Spool File Error; Status action-status. The batch execution server failed trying to open the Spool reference file. The action and status are: action-status Correct the problem with the spool file and retry
CASBJ0014I JOBjob-number started The batch initiator has started processing job-number None
CASBJ0015I message This reports informational messages from the JCL execution engine None
CASBJ0016W message This reports warning messages from the JCL execution engine None
CASBJ0017E message This reports error messages from the JCL execution engine None
CASBJ0018S message This reports severe error messages from the JCL execution engine None
CASBJ0019U message This reports unrecoverable error messages from the JCL execution engine None
CASBJ0020I Batch printer initialization started The batch printer process initialization started None
CASBJ0021I Batch printer started for print output classes "output-classes" The batch printer was started an is available for processing system output. Jobs will be selected from classes output-classes. None
CASBJ0022I Batch printer definition-name: class(es) "print-classes" The batch printer was started an is available for processing output. Job output will be selected from classes print-classes. None
CASBJ0023I Batch initiator definition-name: class(es) "initiator-classes" The batch initiator was started an is available for processing output. Jobs will be selected from classes initiator-classes. None
CASBJ0024I Batch Printer: "printer-name" The batch printer was started and will write to physical printer printer-name. None
CASBJ0025E Printer not found: "printer-name" The physical printer printer-name was not found. Correct the printer name and retry the operation
CASBJ0026I Exit Module: "exit-module" The batch printer is configured to use exit module exit-module. None
CASBJ0027E Printer assignment failed. RC=return-code Call to set assigned printer as the default for this processor failed with a return-code of return-code. Correct the printer name and retry the operation
CASBJ0028E Load failed for exit Module: "exit-module" The batch printer failed to load exit module exit-module. Correct exit module name or location and restart printer
CASBJ0029I print-dataset-title on printer-name The batch printer is printing "print-dataset-title" on printer printer-name None
CASBJ0030E error-message The batch print processor experienced the stated problem. None
CASBJ0031E Printer open failed. RC=return-code Call to open assigned printer failed with a return-code of return-code. Correct the printer problem and retry the operation
CASBJ0032E Printer write failed. RC=return-code Call to write to the assigned printer failed with a return-code of return-code. Correct the printer problem and retry the job
CASBJ0033E Printer error accessing spool data: status-data Print processor encountered an error accessing the spool data. The operation and status is status-data. Correct the problem and retry the job
CASBJ0034I Printer process shutdown complete. The print processor server process has shutdown normally. None.
CASBJ0035I Console input request is pending.# A job or service has requested input from the system console. Reply to the request
CASBJ0036E job-number Spool purge processor not available# Print processor could not locate the Spool purge processor. Correct the problem and restart the print processor
CASBJ0037E job-number Spool purge failed: RC = return-code Print processor failed. The return code was return-code. Correct the problem and restart the print processor
CASBJ0038I job-number Spool SYSOUT Purged Processing of job-number completed and the spool output has been purged None
CASBJ0039E JES support not enabled; Start for Printer rejected The requested Printer was not started because JES support is not enabled. Enable support and retry the operation
CASBJ0040E JES support not enabled; Start for Initiator rejected The requested Job Initiator was not started because JES support is not enabled. Enable support and retry the operation
CASBJ0041E Printer JES interface initialization failed. RC=return-code The requested Printer output processor failed to start because JES initialization failed. Where, the possible return code are:
  • RC=20 - printer not found
  • RC=32 - an exception loading the printer exit - for example, printer exit module not found.
  • RC=100+ - printer exit return code. If the printer exit returns a non-zero return code, 100 will be added to this return code and this becomes the return code from the printer initialization.
Contact technical support with the return code received from casspool
CASBJ0042E Batch initiator JES interface initialization failed. RC=return-code The requested initiator JES interface failed Contact technical support with the return code received from casspool
CASBJ0043E JOB Submit JES interface initialization failed. RC=return-code The requested JOB Submit JES interface failed Contact technical support with the return code received from casspool
CASBJ0044I Batch initiator restart requested for job classes "job-classes" A batch initiator is terminating because of a "dirty container" condition. It has requested that ES start a replacement for the classes "job-classes". None
CASBJ0045I JOB%job-number, DD number dd-number, size dataset-size requested [An external process requested this dataset and transmission has started None
CASBJ0046S JES Submit: User ID "user-ID" invalid or password incorrect A job submission request was submitted but the associated user ID was invalid or the supplied password was incorrect Correct the credentials and retry the operation
CASBJ0047S JES Submit: User ID "user-ID" not authorized A job submission request was submitted but the associated user ID is not authorized for this action Retry the operation with authorized credentials
CASBJ0048S JES CASOUT: User ID "user-ID" invalid or password incorrect An attempt was made to interact with a batch initiator, printer or retrieve spool information and the associated user ID was invalid or the supplied password was incorrect Correct the credentials and retry the operation
CASBJ0049S JES CASOUT: User ID "user-ID" not authorized An attempt was made to interact with a batch initiator, printer or retrieve spool information and the associated user ID is not authorized Retry the operation with authorized credentials
CASBJ0050E JES support not enabled; Job rejected The requested job was not submitted because JES support is not enabled. Enable support and retry the operation
CASBJ0051E Batch initiator JES interface initialization failed for ES Cluster manager ES Cluster manager APPLID. RC=return-code The requested initiator JES interface failed to connect to ES Cluster manager Correct the error and retry the operation
CASBJ0052S Batch initiator JES interface initialization failed for ES Cluster manager ES Cluster manager APPLID. RC=return-code Connection to the ES Cluster manager is lost, ES Cluster member cannot participate to the ES Cluster Check that the connection to the GLM is active