EP - series

EP0001E An exception occurred: 0
Description: An exception occurred.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0002I "Exception" or "Inner exception" stack trace: stacktrace
Description: An exception occurred.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0003E Transaction 'Transaction name' ABEND abendcode, (resp). Backout successful.
Description: A transaction abended with no exception occurred.
  • System action: none
  • User response: Use the abendcode and resp code to help isolate and rectify the problem
  • module: seesep
EP0004E Invalid command-line option: -proxy cannot be specified with other options
Description: A syntax error on the command line was detected.
  • System action: Operation terminates
  • User response: Fix the command line and try again
  • module: seesep
EP0005E Invalid command-line option: -session_service value must be in double quotes
Description: A syntax error on the command line was detected.
  • System action: Operation terminates
  • User response: Fix the command line and try again
  • module: seesep
EP0006I Run svcutil.exe to generate SEP proxies. Press OK to terminate
Description: The required SEP proxies do not seem to be in place.
  • System action: none
  • User response: Run the Svcutil utility to rectify the problem and try again
  • module: seesep
EP0007E An exception occurred: exception
Description: An exception occurred.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0008E Invalid command-line option: -configuration_service value must be in double quotes
Description: Invalid command line syntax detected.
  • System action: Operation terminates
  • User response: Correct the command line syntax and try again
  • Module: seesep
EP0009E Invalid command-line option: -event_monitor_service value must be in double quotes
Description: Invalid command line syntax detected.
  • System action: Operation terminates
  • User response: Correct the command line syntax and try again
  • Module: seesep
EP0012E An exception occurred: exception
Description: An exception occurred.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0016E Error invoking program: Program Name Exception
Description: An error was detected running the program.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0017E Details for request Request ID not found
Description: An error was detected processing the request.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0018E Transaction 'Transaction ID' is not recognized. Check that the transaction name is correct.
Description: An error was detected whilst attempting to execute the given transaction.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0019E An exception occurred: exception
Description: An exception occurred.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0020I PLTPI - No PLT Specified
Description: No PLT was specified.
  • System action: none
  • User response: none
  • Module: seesep
EP0021I PLTPI - List(PLT list name) Processing Started
Description: Processing started.
  • System action: none
  • User response: none
  • Module: seesep
EP0022I PLTPI - List(PLT list name) Processing Completed
Description: Processing completed.
  • System action: none
  • User response: none
  • Module: seesep
EP0023W PLTPI - PLT List PLT list name not found
Description: No PLT List was specified.
  • System action: none
  • User response: none
  • Module: seesep
EP0024W PLTPI - List(PLT list name) PLT program program name not found
Description: PLT program was not found.
  • System action: none
  • User response: Ensure the missing program is available and restart the region
  • Module: seesep
EP0025E PLTPI - List(PLT list name) Program=program name abend
Description: An abend condition was detected during PLTPI processing.
  • System action: Operation terminates
  • User response: Fix the offending program and try again
  • Module: seesep
EP0026I Loaded program program name from path
Description: The specified program was loaded from the location.
  • System action: none
  • User response: none
  • Module: seesep
EP0027E Terminal terminal id does not exist. Unable to start transaction transaction id.
Description: The specified Terminal does not exist, and therefore the system could not start the transaction.
  • System action: The transaction is not run
  • User response: This might be an application error, in an EXEC CICS START request or similar. Correct the application or ensure the required terminal is connected
  • Module: seesep
EP0028E Cannot specify '-configuration_service' or '-session_service' with '-debug'
Description: Invalid command line syntax detected.
  • System action: Operation terminates
  • User response: Correct the command line syntax and try again
  • Module: seesep
EP0029E Invalid '-match" value
Description: Invalid command line syntax detected.
  • System action: Operation terminates
  • User response: Correct the command line syntax and try again
  • Module: seesep
EP0030E Failed to register with event monitor (RC=Return code from event monitor registration)
Description: The SEP could not register with the event monitor.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0031E An exception occurred: exception
Description: An exception occurred.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0032E Region region name is not enabled for dynamic debugging
Description: The specified region is not enabled for dynamic debugging.
  • System action: Dynamic debugging is not allowed
  • User response: Configure the region for dynamic debugging using the administration tool, and retry the operation
  • Module: seesep
EP0033E Failed to connect to region region name
Description: The region requested could not be reached.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0034E Failed to start SEP process
Description: The SEP process could not be started.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0035E Started SEP failed to register with the region region name
Description: The SEP started but could not register itself with the region.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0036I PLTPI Phase 2 - No PLT Specified
Description: No PLT was specified, so no PLT processing occurred.
  • System action: none
  • User response: none
  • Module: seesep
EP0037I PLTPI Phase 2 - List(PLT list name) Processing Started
Description: PLT processing started.
  • System action: none
  • User response: none
  • Module: seesep
EP0038I PLTPI Phase 2 - List(PLT list name) Processing Completed
Description: PLTP processing completed.
  • System action: none
  • User response: none
  • Module: seesep
EP0039W PLTPI Phase 2 - PLT List PLT list name not found
Description: The specified PLT list was not found.
  • System action: none
  • User response: Determine the reason for the missing PLT list and rectify
  • Module: seesep
EP0040W PLTPI Phase 2 - List(PLT list name) PLT program program name not found
Description: The PLT program specified was not found.
  • System action: none
  • User response: Make sure that the PLT program is on one of the configured paths and retry
  • Module: seesep
EP0041E PLTPI Phase 2 - List(PLT list name) Program=program name abend
Description: An abend occurred during PLTP program execution.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0042I PLTSD - No PLT Specified
Description: No PLT was specified.
  • System action: none
  • User response: none
  • Module: seesep
EP0043I PLTSD - List(PLT list name) Processing Started
Description: PLT processing started.
  • System action: none
  • User response: none
  • Module: seesep
EP0044I PLTSD - List(PLT list name) Processing Completed
Description: PLT processing completed.
  • System action: none
  • User response: none
  • Module: seesep
EP0045W PLTSD - PLT List PLT list name not found
Description: PLT not found.
  • System action: none
  • User response: Check the configuration and ensure that the specified list is configured
  • Module: seesep
EP0046W PLTSD - List(PLT list name) PLT program program name not found
Description: The program name was not found.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0047E PLTSD - List(PLT list name) Program=program name abend
Description: The program abended.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0048I PLTSD Phase 2 - No PLT Specified
Description: No PLT was specified.
  • System action: none
  • User response: none
  • Module: seesep
EP0049I PLTSD Phase 2 - List(PLT list name) Processing Started
Description: LT processing has started.
  • System action: none
  • User response: none
  • Module: seesep
EP0050I PLTSD Phase 2 - List(PLT list name) Processing Completed
Description: PLT Processing completed.
  • System action: none
  • User response: none
  • Module: seesep
EP0051W PLTSD Phase 2 - PLT List PLT list name not found
Description: PLT List not found.
  • System action: none
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0052W PLTSD Phase 2 - List(PLT list name) PLT program program name not found
Description: PLT program not found.
  • System action: none
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0053E PLTSD Phase 2 - List(PLT list name) Program=program name abend
Description: PLT processing encountered an abend in the specified program.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0054I native ES message
Description: A message was received from a native enterprise server.
  • System action: none
  • User response: none
  • Module: seesep
EP0055I JCL submit native ES message:1 initiated, type 2
Description: A JCL job was submitted to a native enterprise server.
  • System action: none
  • User response: none
  • Module: seesep
EP0056E JCL submit native ES message:1 failed, type 2 RC=3 request queued
Description: JCL submission failed.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0057I JCL Job Number native ES message
Description: Job submitted with native ES job number.
  • System action: Operation terminates
  • User response: none
  • Module: seesep
EP0058I Unable to debug as region region name is not started
Description: Can’t start a debug session as the target region is not running.
  • System action: Operation terminates
  • User response: Start the region and try the operation again
  • Module: seesep
EP0059E The WCF service endpoints could not be opened. Check that you are authorized to use the Net.Tcp Port Sharing Service. See "WCF Authorization" in the Enterprise Server for .NET documentation for more information.
Description: WCF endpoints are not responding.
  • System action: Operation terminates
  • User response: Make sure that the WCF infrastructure has been initialized correctly
  • Module: seesep
EP0060E Unable to retrieve identity for user ID 0.
Description: The SEP could not retrieve information for the user from the Event Monitor.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem. Ensure the user has signed on to the region since it was last started
  • Module: seesep
EP0061E Error releasing ENQ (QNAME=resource QNAME, RNAME=resource RNAME)
Description: A release enq failed.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0062E Invalid BMS map location type specified (type=BMS map location type)
Description: A path to BMS map locations is invalid.
  • System action: Operation terminates
  • User response: Correct the BMS path and retry
  • Module: seesep
EP0063E Invalid program location type specified (type=program location type)
Description: An invalid program location was specified.
  • System action: Operation terminates
  • User response: Correct the program locations path and retry
  • Module: seesep
EP0064E No event monitor running and unable to start one
Description: An event monitor is not running and starting a new one failed.
  • System action: Operation terminates
  • User response: Check event monitor configuration. Check the service is installed, and is configured correctly
  • Module: seesep
EP0065W Shared memory reallocated by another transaction Expected memory length : Expected memory length Expected start address: Expected start address Expected end address: Expected end address Expected memory type: Expected memory type Actual memory length: Actual memory length Actual start address: Actual start address Actual end address: Actual end address Actual memory type: Actual memory type
Description: A shared memory area was reallocated by another transaction.
  • System action: none
  • User response: none
  • Module: seesep
EP0066E Error processing request message for request request id Exception message: exception message
Description: An exception occurred.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0067E Invalid request for program 'program name'
Description: An invalid request for the specified program was received.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0068E Failed to load JES engine 'JES engine assembly name'
Description: An exception occurred.
  • System action: The JES engine is unavailable for processing.
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0069E An exception occurred processing JCL submission request: message
Description: An exception occurred.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0070E JOB Submit JES interface initialization failed. RC=CASSPOOL initialisation return-code
Description: During a job submit operation, the JES interface failed to initialize with the specified return code.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0071E CASA_Sub_JCL: Missing or invalid job submission request
Description: The job submission request was invalid.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0072E Details for spool id spool id of job requested for execution not found
Description: The spool id for the requested job execution does not exist.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0073E JOB execution JES interface initialization failed. RC=CASSPOOLreturn-code
Description: The JES interface failed to initialize during job execution.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0074E An exception occurred while running JOBNAME=Job name,JOBNUM=Job number Exception message
Description: An exception occurred.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0075E Error executing program program name exception message
Description: An exception occurred.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0076E Job submission failed. No -x parameter received for session 'session identifier'
Description: A job submission request from the administration console, the cassub utility, or another source was rejected because the request was missing required information.
  • System action: The request is rejected
  • User response: Contact Technical Support
  • Module: seesep
EP0077E Invalid CASOUT request CASA_Out_JCL:
Description: A request to the CASA_Out_JCL service is invalid.
  • System action: none
  • User response: Contact Technical Support
  • Module: seesep
EP0078E CASOUT JES interface initialization failed. RC=CASSPOOL initialisation return-code
Description: The JES interface failed to initialize with the given return code.
  • System action: Operation terminates
  • User response: Look up the CASSPOOL return code in the native enterprise server documentation and rectify the problem
  • Module: seesep
EP0079E Invalid input parameter 'invalid input parameter' CASA_Out_JCL:
Description: An invalid input parameter was detected.
  • System action: Operation terminates
  • User response: Correct the input and try again
  • Module: seesep
EP0080E Missing or invalid CASOUT request CASA_Out_JCL:
Description: The casout request is either missing or invalid.
  • System action: Operation terminates
  • User response: Correct the request and try again
  • Module: seesep
EP0081E Unsupported function 'unsupported function' CASA_Out_JCL:
Description: The specified function is unsupported.
  • System action: Operation terminates
  • User response: Consider alternative ways of accomplishing this task. If the unsupported functionality is critical to your application, contact Technical Support
  • Module: seesep
EP0082E Invalid job or dd for 'job number'. Retrieval request ignored CASA_Out_JCL:
Description: An invalid job or dd name was detected.
  • System action: Operation terminates
  • User response: Correct the request and try again
  • Module: seesep
EP0083E Invalid job number: job number CASA_Out_JCL:
Description: An invalid job number was specified.
  • System action: Operation terminates
  • User response: Correct the request and try again
  • Module: seesep
EP0085E Job job number is not on the "Output Hold" queue CASA_Out_JCL
Description: The requested job number is not on the output hold queue.
  • System action: none
  • User response: Correct the request and try again
  • Module: seesep
EP0086E Failure to move job job number to the "Input" queue CASA_Out_JCL:
Description: The specified job number could not be moved to the Input queue.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0087E Job job number0 not found CASA_Out_JCL
Description: The specified job number was not found.
  • System action: Operation terminates
  • User response: Correct the job number and try the operation again
  • Module: seesep
EP0088E Restart processing not enabled CASA_Out_JCL:
Description: Restsart processing is not enabled.
  • System action: Operation terminates
  • User response: If you wish to use restart processing, modify the configuration to do so
  • Module: seesep
EP0089I Job job number removed from input-queue CASA_Out_JCL:
Description: The specified job number was removed from the input queue.
  • System action: none
  • User response: none
  • Module: seesep
EP0090I Kill for job job number issued CASA_Out_JCL:
Description: A kill request for the specified job number has been issued.
  • System action: none
  • User response: none
  • Module: seesep
EP0091W Job job number is not active. Kill request ignored CASA_Out_JCL
Description: A kill request for the specified job number was received, but the job is not active.
  • System action: Operation terminates
  • User response: none
  • Module: seesep
EP0092I Job job number flushed CASA_Out_JCL:
Description: The specified job number was flushed.
  • System action: none
  • User response: none
  • Module: seesep
EP0093W Job 0 not flushed Job number 2 CASA_Out_JCL:
Description: The specified job number was not flushed.
  • System action: Operation terminates
  • User response: none
  • Module: seesep
EP0094I Cannot debug a 'actual region type' region using 'specified region type' match criteria
Description: A CICS SEP must be used to debug a CICS region; a JES SEP must be used to debug a JES region.
  • System action: none
  • User response: Correct the parameters for the debug SEP and try again
  • Module: seesep
EP0095I JESPI - No exit specified
Description: No exit was specified.
  • System action: none
  • User response: none
  • Module: seesep
EP0096I JESPI Phase 2 - No exit specified
Description: No exit was specified.
  • System action: none
  • User response: none
  • Module: seesep
EP0097I JESSD - No exit Specified
Description: No exit was specified.
  • System action: none
  • User response: none
  • Module: seesep
EP0098I JESSD Phase 2 - No exit Specified
Description: No exit was specified.
  • System action: none
  • User response: none
  • Module: seesep
EP0099E Invalid remote catalog request SEE_Catalog:
Description: An invalid remote catalog request was received.
  • System action: The request is ignored
  • User response: If necessary, correct the request and try again
  • Module: seesep
EP0100E PRINT execution JES interface initialization failed. RC= CASSPOOLreturn-code
Description: The JES interface initialization failed for the specified operation with a return code.
  • System action: Operation terminates
  • User response: Look the return code up in the JCL documentation and fix the problem
  • Module: seesep
EP0101E An exception occurred while printing JOBNAME= Job name,JOBNUM=1 Exception message
Description: An exception occurred.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0102E Failed to retrieve spool record spool record for printing
Description: Failed to retrieve the given spool record for printing.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0103I SEP worker role is being stopped - terminating active work
Description: The SEP worker role is being stopped. All active work is being terminated.
  • System action: Active work is being terminated in anticipation of the SEP worker role terminating
  • User response: none
  • Module: seesep
EP0104I Job job number released: return code CASA_Out_JCL:,
Description: The job was released with the given return code.
  • System action: none
  • User response: none
  • Module: seesep
EP0105E Job job number is not in the Input Hold queue: return code
Description: The specified job number is not in the input hold queue.
  • System action: Operation terminates
  • User response: Correct the request and try again
  • Module: seesep
EP0106E Job job number does not exist: return code
Description: The specified job number does not exist.
  • System action: Operation terminates
  • User response: none
  • Module: seesep
EP0107I Job job number requeued from class original job class to new job class: return code
Description: The specified job number was requeued to a new class.
  • System action: none
  • User response: none
  • Module: seesep
EP0108E Unknown return code - job job number: return code
Description: The specified job returned an unknown return code.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0108W Failed to pre-load assembly 'assembly name'
Description: The specified assembly could not be preloaded.
  • System action: preload terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0110E Invalid initiator id 'initiator id'
Description: The specified initiator ID is invalid.
  • System action: Operation terminates
  • User response: Specify the correct initiator ID and try again
  • Module: seesep
EP0111E Initiator with id 'initiator id' not found
Description: The specified Initiator ID was not found.
  • System action: Operation terminates
  • User response: Check the console log and Applications and Services Logs > Micro Focus Server category of the Windows event log for further information to help resolve the problem
  • Module: seesep
EP0112I Initiator enabled
Description: The initiator was enabled.
  • System action: none
  • User response: none
  • Module: seesep
EP0113I Initiator disabled
Description: The initiator was disabled.
  • System action: none
  • User response: none
  • Module: seesep
EP0114E Invalid printer id 'printer id'
Description: The specified printer is invalid.
  • System action: Operation terminates
  • User response: Make sure that the requested printer infrastructure exists and retry the operation
  • Module: seesep
EP0115E Printer with id 'printer id' not found
Description: The specified printer is invalid.
  • System action: Operation terminates
  • User response: Make sure that the requested printer infrastructure exists and retry the operation
  • Module: seesep
EP0116I Printer enabled
Description: The Printer is enabled.
  • System action: none
  • User response: none
  • Module: seesep
EP0117I Printer disabled
Description: The printer is disabled.
  • System action: none
  • User response: none
  • Module: seesep