Skip to content

More Settings RLogin Dialog Box

How do I get to this dialog box?
  1. Open a VT terminal session.

  2. Under Host Connection, click Configure Connection Settings.

  3. Open the Settings window.

    The steps depend on your user interface mode.

    User interface mode Steps
    Ribbon or InfoConnect Browser With a session open, from the Quick Access Toolbar, click .
    TouchUX With a session open, tap the Gear icon and then select Document Settings.
    Classic MDI With a session open, go to Options > Settings.
  4. Under Connection Method, select Network.

  5. Under Network Connection Type, select Rlogin.

  6. Under Connection Options, click the More Settings button.

The options are:

Option Description
TCP port When connecting to a host via Rlogin, most hosts wait for an incoming connection on TCP Port 513. If your host uses a different port, type that number here.
Parity This setting determines whether a parity bit is generated for each character transmitted. Parity is used to detect errors in data transmission; the number preceding the slash indicates the number of data bits sent.

To use the multinational character set or 8-bit controls, Parity must be set to one of the values that offers 8-bit controls. If your communications link generates parity, and you set Parity to 8/None, multinational characters appear on your screen. In this case, set Parity to either 8/Even or 8/Odd.
Baud Select the rate at which InfoConnect transmits and receives data through the network connection.
Terminal type To override the default terminal, select or type a value here. In general, you control the following characteristics when you change terminal types:

Which screen control sequences the host sends to InfoConnect to format the screen.

The position of the cursor. , Which characters to display in a host application.

.

If you're having trouble running a host application, the negotiation between InfoConnect and the host might be wrong. If you enter a terminal type that the host does not recognize, InfoConnect reverts to a list of default values until one is found that the host supports.
Timeout Specify the number of milliseconds InfoConnect should attempt to make a connection before timing out. The maximum value is 65535. The timeout period begins after host name resolution has taken place. This means an additional delay, usually a few seconds beyond the value specified. When this is set to 0 (the default), InfoConnect timeout behavior is determined by your Windows operating system.
Session limits Select the maximum number of sessions you want to allow for a Telnet connection.
Close on disconnect Select to close your session document when you disconnect from the host.

More information