Skip to content

InfoConnect Desktop 18.0 Release Notes

Last Updated: December 2022

Introduction

InfoConnect Desktop products are full-featured desktop applications that allow you to run host applications, transfer files, and integrate host data into the latest Windows and Office software applications.

  • InfoConnect Desktop Pro for Unisys is a Windows-based terminal emulator that connects users to Unisys, T27, UNIX, Linux, OpenVMS, IBM, and HP 3000 hosts.

  • InfoConnect Desktop Pro for Unisys with X includes all the functionality of InfoConnect Desktop Pro for Unisys, plus Reflection X, an X server that allows you to view your UNIX desktop and work with X client applications from a remote workstation.

  • InfoConnect Desktop Pro for Airlines is a family of Windows-based terminal emulators, print delivery options, and software development tools built specifically for the airline industry. These products enable users to access and print from multiple systems, including TPF, ALCS, IBM, Unisys, UNIX, Linux, HP 3000, and Global Distribution Systems.

  • InfoConnect Desktop for Airlines Print and Transaction Router (PTR) is flexible print delivery software that complements InfoConnect Desktop Pro for Airlines with support for shared printers and host devices as well as for intelligent card readers, specialized ticket printers, and point-of-sale terminals.

  • The Reflection Desktop for NonStop Add-On is a separately licensed product for connecting to HP NonStop hosts (Tandem 6530).

The InfoConnect Desktop 18.0 release includes a number of new security improvements, new features, and resolved issues.

Many of these improvements were made in direct response to suggestions from our customers. We thank you for your time and valuable input. We hope you continue to help us ensure that our products meet all your needs.

What's New

InfoConnect Desktop v18.0 includes several major new features and enhancements:

InfoConnect Desktop Enhancements

  • Added support for Microsoft Windows 11.

    For a comprehensive list of system requirements see the Hardware Requirements and Supported Operating Systems section.

  • Support for IBM printers is integrated into the workspace. Now you can create, configure, and manage your IBM printer sessions in the same way as your terminal sessions. You can use your current .rsf files in managed sessions. You can also open local .rsf printer session files from previous versions and choose whether to convert them to the new IBM 3270 .rp3x or IBM 5250 .rp5x file formats when you close the sessions. Commonly used Printer .rsf file settings are supported. Some settings that were configured on the legacy View Settings panel are no longer supported.

  • The user interface is modernized to provide a rich user experience. In addition to adding a modern look and feel, the new interface is designed to improve navigation and provide a more consistent and efficient approach for viewing and updating settings.

  • The documentation has a new look and feel and several features designed to improve navigation so you can find the help you need.

  • Added support for native 64-bit HLLAPI applications via WHLLAPI64.dll and EHLAPI64.dll for 3270 sessions.

  • InfoConnect Desktop now uses WebView2 when Web Browser functionality is required, such as when opening a web session.

  • Trusted Locations are now locked down by default. Users with administrative rights on a machine can modify Trusted Locations.

Reflection X Enhancements

  • Reflection X Advantage is now Reflection X. This X server is no longer sold separately and is included as a feature in Reflection Desktop Pro and Reflection Desktop for X.

  • The supported SSH cryptography algorithms are expanded to connect with the default algorithms supported in the latest OpenSSH servers.

    • Added support for the following Key Exchange Algorithms:

      • ECDH-SHA2-NISTP256

      • ECDH-SHA2-NISTP384

      • ECDH-SHA2-NISTP521

    • Added support for the following Host Key Algorithms:

      • ECDSA-SHA2-NISTP256

      • ECDSA-SHA2-NISTP384

      • ECDSA-SHA2-NISTP521

      • RSA-SHA2-256

      • RSA-SHA2-512

  • GLX performance is improved.

  • Expanded new administrative features that are managed via Group Policy:

    • The Import dialog displayed when Reflection X is first launched can now be disabled via Group Policy.

    • Allow Remote IP Connections can now be disabled via Group Policy.

    • Exit program on last client setting can be enabled via Group Policy.

    • X Manager can now be forced to run in FIPS mode via Group Policy.

  • Developed security improvements to Domain Services.

  • Reflection X is now running on Java 17.

Security Enhancements

  • Added an option to specify SOCKS or HTTP proxy Hostname even if it doesn’t resolve to a hostname from the client machine.

  • SOCKS/HTTP proxy settings have been migrated from the registry to the configuration file.

  • Certificate validation has been upgraded to use OpenSSL APIs.

  • Improved the keyboard and audio navigation experience within the Security Properties dialog box.

  • Updated to OpenSSL 3.0.7 to address CVE-2022-3603 and CVE-2022-3786.

  • Updated to the latest OpenSSL version to address CVE-2022-0778.

Reflection FTP Client Enhancements

  • Added the ability to access the 32-bit Reflection FTP COM interface from 64-bit applications.

  • Reflection FTP Client documentation is available via the web or an installed PDF. The installed PDF is available at the following location:
    <install-path>Micro Focus\InfoConnect\Help\rftp\<language>\rftp.pdf


Resolved Issues

InfoConnect Desktop

  • Users referencing ReflectionCOM using VBA or VBScript can now reference ReflectionCOM in other languages without seeing an exception.

  • Improved the user experience of the SAML Authentication HTML page.

  • Added support to launch multiple host sessions when Centralized Management with SAML is configured.

  • Resolved printer session connectivity issues due to spaces in printer session name when connecting via the Security Proxy.

  • The showlabel checkbox is now disabled by default when a new toolbar button is added in Classic UI mode.

  • Fixed display issues caused by screen resolutions higher than full high definition (HD).

  • Failed Advanced Authentication requests when using x509 smartcards will now alert users that access the application with screen reader software.

  • InfoConnect Desktop when configured with Centralized Management can now authenticate to multiple domains.

  • Resolved performance issues when an InfoConnect event is enabled and data is being displayed from the host.

  • Added support for special characters when using Express Macro Language (EML) macros.

  • Increased the maximum character limit to 128 characters for SSH user names.

  • Improved the message dialogs if errors occur during the initialization of VBA Components.

  • Enhanced support for Python apps and Extra! COM.

  • Fixed HP Terminal connectivity issues when using GetObject with the OLE Server Name.

  • Resolved an issue so users can change the session title when in Classic user interface mode.

  • Improved the scaling of QuickPad text for increased legibility.

  • Fixed display issues for tab Label Names when using a customized Ribbon.

  • Added support for events in the Event Mapper to work when the session is not active.

  • Increased support for Czech and Romanian character entries.

  • Resolved User Interface Designer display issues to show all available controls.

  • Fixed potential keystroke loss in 3270 host sessions and increased the speed of data display.

  • Logging support has been added when the windows temp folder is not accessible or present.

  • When ..\AppData\Roaming\Micro Focus\InfoConnect folder is not accessible InfoConnect Desktop now displays a troubleshooting error message.

  • Restored the option to add the date and time to the status bar.


Security

  • Changed the behavior of sftp uploads when disk space issues are present. When an sftp upload is terminated, the upload will only show the successfully uploaded data.

Reflection X

  • Improved installer feature tree usability when modifying a custom installation.

  • Fixed the display coloring on Gnome 3 desktop when runing on Oracle Solaris 11.4 on SPARC.

  • Resolved character display issues when using the indirect rendering option for the GLX extension.

  • Fixed Secure Shell user key settings.

    When the setting Remember user key for... is enabled, and Always prompt for user key... is disabled users will no longer be prompted to select a user key when launching a session.

Known Issues

  • Product documentation has been updated for this release and rendering issues can be experienced in environments with older web platforms such as Internet Explorer. Please install webview2, which is a modern web platform to navigate the product documentation.

System Requirements

InfoConnect Desktop

For information about supported platforms and hardware requirements for InfoConnect Desktop, see System Requirements in the Administrative Guide.

Note

InfoConnect Desktop 18.0 requires a 64-bit operating system.

For more information about installing InfoConnect Desktop, see the InfoConnect Help and the InfoConnect Deployment Guide.

Reflection X

For information about supported platforms and hardware requirements for Reflection X, see System Requirements in the Reflection X Help. For more information about installing Reflection X, see the Reflection X Help and the Reflection X Administrative Guide.

Note

Reflection X 18.0 requires a 64-bit operating system that supports Java 17.

Reflection X requires Java 17. By default, Reflection X installs and uses a private Java Runtime Environment (JRE) that is correctly configured to fully support all Reflection X features. It is also possible to configure Reflection X running on Windows to use a different JRE.

Previous Releases

For information about the InfoConnect Desktop 18.0 release, see the InfoConnect Desktop 17.0 SP1 Release Notes and the InfoConnect Desktop 17.0 SP1 Update 1 Release Notes.

Contacting Micro Focus

For specific product issues, contact Micro Focus Support.

Additional technical information or advice is available from several sources:

© Copyright 2022 Micro Focus or one of its affiliates.

The only warranties for products and services of Micro Focus and its affiliates and licensors ("Micro Focus") are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. Micro Focus shall not be liable for technical or editorial errors or omissions contained herein. The information contained herein is subject to change without notice. Please see the product’s applicable end user license agreement for details regarding the license terms and conditions, warranties, and limitations of liability.

Any links to third-party websites take you outside Micro Focus websites, and Micro Focus has no control over and is not responsible for information on third party sites.