CBL_WRITE_SCR_N_CHAR

Writes a specified character to a string of positions on the screen.

Restriction: This routine is supported for native COBOL only.

Syntax:

call "CBL_WRITE_SCR_N_CHAR"  using     screen-position
                                      character
                                      fill-length
                            returning status-code

Parameters

screen-position
Group predefined as cblt-screen-position containing:
01 cblt-screen-position   typedef.
  03 cblte-scrp-row       cblt-x1-compx. 	*> pic x comp-x.
  03 cblte-scrp-col       cblt-x1-compx. 	*> pic x comp-x.
character
Call prototype (see Key): pic x1-compx
Picture: pic x.
fill-length
Call prototype (see Key): pic x2-compx
Picture: pic x (2) comp-x.
status-code
See Library Routines - Key.

On Entry:

screen-position The screen position at which to start writing. The top left corner is row 0, column 0. See Screen Routines
attribute-buffer The attributes to write.
string-length The number of screen positions to write the character to. If this would go off the end of the screen, the write finishes at the end of the screen.

On Exit:

None