Enabling Raw Measure Data Capturing

  1. In Silk Performer, expand the Profiles node in the Project tree.
  2. Right-click the profile that you want to configure and choose Edit Profile.
    Tip: Alternatively, you can choose Settings > Active Profile from the menu bar.

    The Profile - [<profile name>] dialog box opens, and the Replay category is displayed in the shortcut list on the left.

  3. In the shortcut list on the left, click the Results icon.
  4. Click the Measures tab.
  5. Check the Collect raw measure data check box.

To configure raw measure data capturing for particular measure types or single measures, use the BDL function MeasureCollectRawData.