Skip to content

Miscellaneous

  • Autogroom the TracePlayer File

    When this check box is selected (the default), the TracePlayer file used by Host Emulator is autogroomed after the recording is complete.

  • Caps Lock State

    Specifies whether the Design Tool is in Caps Lock mode. The default is No. This state is not saved as part of a model or settings file.

  • Caption

    Specifies the string that appears in the Design Tool title bar. This string is relevant only when the Help display mode is Status Bar (default). This string is also displayed on the taskbar when the Design Tool is running.

    Select a predefined option from the list box, or enter up to 260 characters in the box. As you click on predefined options, shortcuts for these options are added to the box. The predefined options and their shortcuts are:

    Shortcut Option
    &r "Verastream Host Integrator"
    &f Model file name (or "Untitled" if a model file is not open)
    &s Session type
    &t Transport
    &h Host name
    &d Date
    &c Connection status
    &v Assigned device name
    && Single ampersand
    &p Script debugging port

    So, for example, if you set the Caption to &s - &t - &c, you might see "IBM 5250 Terminal - Telnet - Connected" in the Design Tool title bar or on the taskbar, assuming the Design Tool is running but not minimized. The default is &f - &r - &s.

  • Case Sensitive Search

    Select this option to use case sensitive criteria when searching for tables and elements in both the Tables and Import Model Elements dialog boxes. By default searches are case insensitive.

  • Close Progress Window on Completion

    The Host Integrator progress window displays information about the progress of navigation or event handling sequences. The progress window is displayed when a sequence takes longer than one-half second. You can force the progress window to stay open by changing this setting to No. The default is Yes.

    If set to No, a login or logout process can stall when a dialog box requires user input. You must click Close so that the login or logout process can continue.

  • Command Line Switches (read-only)

    Shows command line switches (also called command line parameters), if any, that were used to start the Design Tool.

  • Confirm Exit

    Select this option if you want the Design Tool to display a confirmation dialog box before exiting.

  • Connect To Host on Open

    Specifies whether you want the Design Tool to automatically connect to the host when you load a model file.

  • Convert Alternate Font Characters to Spaces

    Specifies how to handle characters that are not part of the default character set. For example, VT line drawing characters in a character mode application are not part of the ANSI character set. If this setting is set to Yes, Host Integrator will translate all such characters to spaces when reading them from the screen buffer. The default is No, which means that Host Integrator will read and store the numerically equivalent ANSI character instead.

  • Display small icons in the Navigator dialog (read-only)

    Reflects the Host Integrator Navigator utility option to display small icons instead of the default large icons.

  • Don't Show Discard Recording Dialog Box

    Specifies whether or not to display the Discard Recording dialog box each time a record trace is deleted. The default is No.

  • Don't Show the Hidden Variable in Descriptor Security Warning Dialog Box

    Select Do not display the message again to hide the security warning regarding the display of hidden variable values as plain text within descriptor files. To secure sensitive information, it is best practice to use the Administrative Console to enter the variable values.

  • Don't Show Save Entity Dialog Box

    Specifies whether or not to display the Apply Changes dialog box each time an entity is modified. The default is No.

  • Execute Host Login Sequence on Host Connect

    Specifies whether the Design Tool will execute a login command list when your model connects to a host.

    You can also enable this setting from the General tab of the Preferences Setup dialog box by selecting the Execute login commands check box. The default is No.

    This option also navigates to the home entity and initiates associated event handlers.

  • Execute Host Logout Sequence on Host Disconnect

    Specifies whether to execute a logout command list when your model disconnects from a host.

    You can also enable this setting from the General tab of the Preferences Setup dialog box by selecting the Execute logout commands check box. The default is No.

  • Font Character Set

    Specifies the character set that Host Integrator uses for its user interface. The character set values are:

    • Ansi (default)
    • Baltic
    • Chinese Big5
    • East European
    • GB2312
    • Greek
    • Hangeul
    • Hebrew
    • Johab
    • Oem
    • Russian
    • ShiftJis
    • Turkish
  • Max Trace File Length (KB)

    Specifies the maximum size for an internal trace file (.cfgtrc), in kilobytes. The range of values is from 10 to 65,535 KB. The default is 10,000 KB.

  • Maximum Number of Consecutive Session View Partial Updates Allowed

    Specifies the maximum number of partial screen updates that will be accepted by a Host Integrator Server from a character mode host. Partial updates are commonly sent via a datastream of characters on character mode hosts unlike block mode hosts, which often transmit one screen's worth of data at a time. The default is 5.

  • Maximum Size (KB) for Session View Buffered Data

    Specifies the maximum limit of memory that is used when a Host Integrator Server stores host data for the Session Monitor. The default is 1,024 KB.

    When a Host Integrator Server receives data from a host, it buffers that data until it can be used by the Session Monitor. During a host session, the Session Monitor requests the data from the Host Integrator Server and the buffered data is sent. Setting a maximum limit of memory on the Host Integrator Server creates a type of load balancing between the server and the Session Monitor that enables optimum performance. Once this memory limit is exceeded, the memory is deleted and the following log message appears in the Session Server log:

    Since the buffer size of the maximum session view exceeded its limit, one or more session view displays were lost.

  • Maximum Size for Debug Trace Output File

    Specifies the maximum size for debug trace output files. The range of values is from 0 to 1024 MB. If you specify 0, no size limit is enforced.

  • Maximum Size Design Tool Model Debug Message Store

    Specifies the maximum size for the model debug messages store. The range of values is from 1 to 1000 MB. The default is 128.

  • Mouse Last-Clicked Column

    Specifies the column number where the mouse was located the last time the left button was clicked.

  • Mouse Last-Clicked Row

    Specifies the row number where the mouse was located the last time the left button was clicked.

  • Numlock State

    Specifies whether Host Integrator is in Num Lock mode. The Design Tool does not change the state of Num Lock, although the model can affect the Num Lock setting if the state of Num Lock is changed as part of building or loading a model. This state is not saved as part of a model or settings file.

  • Path and Name of Executable (read-only)

    Returns the full path and filename (including the drive letter) for the Host Integrator Design Tool executable file.

  • Path to Executable (read-only)

    Returns the full path (including the drive letter) for the Host Integrator Design Tool executable file.

  • Pause Playback Trace on EOR

    Specifies what happens when an end-of-record character is encountered during playback of a trace file. When set to Yes (default), the playback pauses at the end of each record. When set to No, the playback runs to completion without pausing.

  • Procedure Navigates to Home Entity When an Error Occurs

    Specifies whether or not a procedure automatically traverses to the home entity when an error occurs. The default is Yes.

  • Read Hidden Text

    Specifies whether or not the Design Tool should be able to recognize hidden text on the terminal screen.

  • Record Initial Synchronization Commands

    Specifies whether the recorder (used in manual recording and by character mode applications) starts each recording session with synchronization commands. If this setting is enabled, these commands will be recorded at the start of each generated operation in character mode and in each manually recorded command list or operation. The default is Yes.

  • Recording (read-only)

    Specifies whether or not the command list recorder is on.

  • Save Model

    Specifies whether you want to automatically save your model when you exit the Design Tool.

  • Scroll Lock State

    Specifies the state of Scroll Lock in Host Integrator. This state is not saved as part of a model or settings file.

  • Secondary Selection End Column (read-only)

    Returns the ending column for the pattern definition location. This setting applies when defining a pattern in an expanded region.

  • Secondary Selection End Row (read-only)

    Returns the ending row for the pattern definition location. This applies when searching for a pattern in an expanded region.

  • Secondary Selection Start Column (read-only)

    Returns the starting column for the pattern definition location. This applies when defining a pattern in an expanded region.

  • Secondary Selection Start Row (read-only)

    Returns the starting row for the pattern definition location. This applies when defining a pattern in an expanded region.

  • Selection End Column (read-only)

    Returns the ending column for the current selection.

  • Selection End Row (read-only)

    Returns the ending row for the current selection.

  • Selection Start Column (read-only)

    Returns the starting column for the current selection.

  • Selection Start Row (read-only)

    Returns the starting row for the current selection.

  • Serial Number

    Returns the serial number of your copy of Host Integrator.

  • Show Progress Details

    The Host Integrator progress window displays information about the progress of navigation or event handling sequences. The progress window is displayed when a sequence takes longer than one-half second and will remain open after completion if an error occurs. By default, this progress window shows a short progress statement. When Show Progress Details is set to Yes, the details of the sequence are also displayed. If Show Progress Details is set to Yes, you can also force the progress window to stay open by using the setting Close Progress Window on Completion.

  • Startup Working Directory (read-only)

    Specifies the working directory for the current session.

  • Translation Character Set (read-only)

    Indicates the type of translation taking place between the Host Integrator client and server, based on the type of terminal session and the international (National Character Set) setting. This setting is particularly useful for technical support personnel.

    In the Design Tool, the setting indicates the international characters displayed in the terminal window and in certain internationalized dialog boxes.

    On the server, the setting determines which single-byte to Unicode translation will be used when communicating with a Host Integrator client.

    Possible values are:

    • ISO-8859—default. This is the character set used on Microsoft Windows for the US, Western Europe, and Latin America. All VT, HP, and most 3270 and 5250 Host Integrator sessions use this character set.
    • Thai—Used only for Thai 3270 or 5250 terminal sessions.
    • Baltic—Used only for Baltic 3270 sessions.
    • Greek—Used only for Greek 3270 or 5250 sessions.
    • Turkish—Used only for Turkish 3270 or 5250sessions.
    • East Europe—Used only for East European 3270 or 5250sessions.
    • Cyrillic—Used only for Cyrillic 3270or 5250 sessions.
    • Custom—Used for custom sessions.
  • Use model file host settings for design tool deployment

    The host connection settings specified in the Session Settings dialog box (available by choosing Session Setup from the Connection menu) are used when deploying the model from within the Design Tool. If set to No, a separate host name and port number must be specified on the Deployment Options tab available from the File menu. The default is Yes.

  • User Recording (read-only)

    Use to manually record commands in Host Integrator

  • Version String (read-only)

    Returns the version number of your copy of Host Integrator.